| Number of inputs |
1 analog, 1 trigger |
| Power supply |
via the K-bus |
| Signal voltage |
UIN: -16…+16 mV |
| Signal voltage UIN |
-20…+20 mV |
| Technology |
high-speed data logger |
| Internal resistance |
> 1 MΩ (UB) |
| Supply voltage |
5 V DC, max. 20 mA |
| Conversion time |
< 100 µs, configurable (10 µs with fast sampling mode) |
| Sampling rate |
< 100 µs, configurable (10 µs with fast sampling mode) |
| Resolution |
14 bit + sign |
| Measurement error/ uncertainty |
< ±1 % (relative to full scale value) |
| Internal memory |
32 kbytes |
| Current consumption power contacts |
– (no power contacts) |
| Current consumption K-bus |
typ. 120 mA with external SG power supply, typ. 140 mA with internal SG power supply from terminal (4 x 350 Ω) |
| Bit width in the process image |
input/output: 1 x 16 bit data (1 x 8 bit status, 1 x 8 bit control) |
| Special features |
high-speed strain gauge analysis (for all fieldbuses) |
| Weight |
approx. 55 g |
| Operating/storage temperature |
0…+55 °C/-25…+85 °C |
| Relative humidity |
95 %, no condensation |
| Vibration/shock resistance |
conforms to EN 60068-2-6/EN 60068-2-27 |
| EMC immunity/emission |
conforms to EN 61000-6-2/EN 61000-6-4 |
| Protect. rating/installation pos. |
IP20/variable |
| Pluggable wiring |
for all KSxxxx Bus Terminals |
| Approvals/markings |
CE, UL, ATEX |
| Ex marking |
II 3 G Ex nA IIC T4 Gc |